Please choose your country
Europe
  • al flag
    Albania (AL)
  • am flag
    Armenia (AM)
  • at flag
    Austria (AT)
  • az flag
    Azerbaijan (AZ)
  • be flag
    • Vlaams
    •  -  Wallon-français
  • by flag
    Bielorussia (BY)
  • ba flag
    Bosnia and Herzegovina (BA)
  • bg flag
    Bulgaria (BG)
  • hr flag
    Croatia (HR)
  • cz flag
    Czech Republic (CZ)
  • dk flag
    Denmark (DK)
  • ee flag
    Estonia (EE)
  • fi flag
    Finland (FI)
  • fr flag
    France (FR)
  • ge flag
    Georgia (GE)
  • de flag
    Germany (DE)
  • gr flag
    Greek (GR)
  • hu flag
    Hungary (HU)
  • is flag
    Iceland (IS)
  • ie flag
    Ireland (IE)
  • it flag
    Italy (IT)
  • kz flag
    Kazakhstan (KZ)
  • lv flag
    Latvia (LV)
  • lt flag
    Lithuania (LT)
  • lu flag
    • Deutsch
    •  -  Français
  • md flag
    Moldova (MD)
  • me flag
    Montenegro (ME)
  • nl flag
    Netherlands (NL)
  • mk flag
    North Macedonia (MK)
  • no flag
    Norway (NO)
  • pl flag
    Poland (PL)
  • pt flag
    Portugal (PT)
  • ro flag
    Romania (RO)
  • rs flag
    Serbia (RS)
  • sk flag
    Slovakia (SK)
  • si flag
    Slovenia (SI)
  • es flag
    Spain (ES)
  • se flag
    Sweden (SE)
  • ch flag
    • Deutsch
    •  -  Français
  • ua flag
    Ukraine (UA)
  • gb flag
    United Kingdom (UK)
Asia
  • cn flag
    China (CN)
  • kr flag
    Korea (KR)
  • ae flag
    United Arab Emirates (الإمارات العربيّة المتّحدة)
Australia
  • au flag
    Australia (AU)
North America
  • ca flag
    • English
    •  -  Français
  • us flag
    United States (USA)
Can't find your country? Please visit www.schoeck.com or contact us on export@schoeck.com
  1. Solutions
    1. Solutions
    2. Overview
    3. Isokorb®
      Thermal protection for cantilevers
      1. Isokorb®
      2. Overview
      3. Balcony and pergola
        Reinforced concrete - Reinforced concrete
        1. Balcony and pergola
        2. Overview
        3. Isokorb® XT with insulating element thickness 120 mm
          1. XT type K
          2. XT type K-F
          3. XT type K-U
          4. XT type K-U-F
          5. XT type K-O
          6. XT type K-O-F
          7. XT type Q
          8. XT type Q-Z
          9. XT type Q-P
          10. XT type Q-PZ
          11. XT type C
          12. XT type H
          13. XT type Z
          14. XT type D
        4. Isokorb® T with insulating element thickness 80 mm
          1. T type K
          2. T type K-F
          3. T type K-U
          4. T type K-U-F
          5. T type K-O
          6. T type K-O-F
          7. T type Q
          8. T type Q-Z
          9. T type Q-P
          10. T type Q-PZ
          11. T type C
          12. T type H
          13. T type Z
          14. T type D
        5. Isokorb® CXT with insulating element thickness 120 mm and glass-fibre composite rods
          1. CXT type K
          2. CXT type K-F
        Isokorb® XT type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        XT type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        XT type K-F

        Load-bearing thermal insulation element for cantilevered balconies. The two-piece version has been optimised for processing in the precast plant.

        XT type K-U

        Load-bearing thermal insulation element for free cantilevered balconies with height offset downwards or wall connection.

        XT type K-U-F

        Load-bearing thermal insulation element for cantilevered balconies with height offset downwards or wall connection. The two-piece version has been optimised for processing in the precast plant.

        XT type K-O

        Load-bearing thermal insulation element for free cantilevered balconies with height offset upwards or wall connection.

        XT type K-O-F

        Load-bearing thermal insulation element for cantilevered balconies with height offset upwards or wall connection. The two-piece version has been optimised for processing in the precast plant.

        XT type Q

        Load-bearing thermal insulation element for supported balconies.

        XT type Q-Z

        Load-bearing thermal insulation element for supported balconies in constraint-free connection.

        XT type Q-P

        Load-bearing thermal insulation element for supported balconies.

        XT type Q-PZ

        Load-bearing thermal insulation element for supported balconies in constraint-free connection.

        XT type C

        Load-bearing thermal insulation element for freely cantilevered corner balconies.

        XT type H

        Load-bearing thermal insulation element for the transmission of planned horizontal forces parallel and perpendicular to the insulation plane.

        XT type Z

        Thermal insulation element as supplement for different installation situations and fire protection requirements.

        XT type D

        Load-bearing thermal insulation element for continuous flooring.

        Isokorb® T type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        T type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        T type K-F

        Load-bearing thermal insulation element for cantilevered balconies. The two-piece version has been optimised for processing in the precast plant.

        T type K-U

        Load-bearing thermal insulation element for free cantilevered balconies with height offset downwards or wall connection.

        T type K-U-F

        Load-bearing thermal insulation element for cantilevered balconies with height offset downwards or wall connection. The two-piece version has been optimised for processing in the precast plant.

        T type K-O

        Load-bearing thermal insulation element for free cantilevered balconies with height offset upwards or wall connection.

        T type K-O-F

        Load-bearing thermal insulation element for cantilevered balconies with height offset upwards or wall connection. The two-piece version has been optimised for processing in the precast plant.

        T type Q

        Load-bearing thermal insulation element for supported balconies.

        T type Q-Z

        Load-bearing thermal insulation element for supported balconies in constraint-free connection.

        T type Q-P

        Load-bearing thermal insulation element for supported balconies.

        T type Q-PZ

        Load-bearing thermal insulation element for supported balconies in constraint-free connection.

        T type C

        Load-bearing thermal insulation element for freely cantilevered corner balconies.

        T type H

        Load-bearing thermal insulation element for the transmission of planned horizontal forces parallel and perpendicular to the insulation plane.

        T type Z

        Thermal insulation element as supplement for different installation situations and fire protection requirements.

        T type D

        Load-bearing thermal insulation element for continuous flooring.

        Isokorb® CXT type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        CXT type K

        Load-bearing thermal insulation element for freely cantilevered balconies.

        CXT type K-F

        Load-bearing thermal insulation element for cantilevered balconies. The two-piece version has been optimised for processing in the precast plant.

      4. Parapet and balustrade
        Reinforced concrete - Reinforced concrete
        1. Parapet and balustrade
        2. Overview
        3. Isokorb® CXT with insulating element thickness 120 mm and glass-fibre composite rods
          1. CXT type A
        4. Isokorb® XT with insulating element thickness 120 mm
          1. XT type A
          2. XT type F
        5. Isokorb® T with insulating element thickness 80 mm
          1. T type A
          2. T type F
        Isokorb® CXT type A

        Load-bearing thermal insulation element for parapets and balustrades.

        CXT type A

        Load-bearing thermal insulation element for parapets and balustrades.

        Isokorb® XT type A

        Load-bearing thermal insulation element for parapets and balustrades.

        XT type A

        Load-bearing thermal insulation element for parapets and balustrades.

        XT type F

        Load-bearing thermal insulation element for curtain parapets and balustrades.

        Isokorb® T type A

        Load-bearing thermal insulation element for parapets and balustrades.

        T type A

        Load-bearing thermal insulation element for parapets and balustrades.

        T type F

        Load-bearing thermal insulation element for curtain parapets and balustrades.

      5. Bracket, beam and wall
        Reinforced concrete - Reinforced concrete
        1. Bracket, beam and wall
        2. Overview
        3. Isokorb® XT with insulating element thickness 120 mm
          1. XT type O
          2. XT type B
          3. XT type W
        4. Isokorb® T with insulating element thickness 80 mm
          1. T type O
          2. T type B
          3. T type W
        Isokorb® XT type O

        Load-bearing thermal insulation element for corbels.

        XT type O

        Load-bearing thermal insulation element for corbels.

        XT type B

        Load-bearing thermal insulation element for cantilever beams and downstand beams.

        XT type W

        Load-bearing thermal insulation element for cross walls.

        Isokorb® T type B

        Load-bearing thermal insulation element for cantilever beams and downstand beams.

        T type O

        Load-bearing thermal insulation element for corbels.

        T type B

        Load-bearing thermal insulation element for cantilever beams and downstand beams.

        T type W

        Load-bearing thermal insulation element for cross walls.

      6. Steel and timber construction
        1. Steel and timber construction
        2. Overview
        3. Isokorb® XT with insulating element thickness 120 mm for steel and timber structures on reinforced concrete
          1. XT type SK
          2. XT type SQ
        4. Isokorb® T with insulating element thickness 80 mm for steel and timber structures on reinforced concrete
          1. T type SK
          2. T type SQ
        5. Isokorb® T with insulating element thickness 80 mm for steel structures on steel
          1. T type S
        Isokorb® XT type SK

        Load-bearing thermal insulation element for freely cantilevered steel constructions with connection to reinforced concrete floors.

        XT type SK

        Load-bearing thermal insulation element for freely cantilevered steel constructions with connection to reinforced concrete floors.

        XT type SQ

        Load-bearing thermal insulation element for supported steel constructions with connection to reinforced concrete floors.

        Isokorb® T type SK

        Load-bearing thermal insulation element for freely cantilevered steel constructions with connection to reinforced concrete floors.

        T type SK

        Load-bearing thermal insulation element for freely cantilevered steel constructions with connection to reinforced concrete floors.

        T type SQ

        Load-bearing thermal insulation element for supported steel constructions with connection to reinforced concrete floors.

        Isokorb® T type S

        Load-bearing thermal insulation elements for the connection of freely cantilevered steel constructions to steel structures.

        T type S

        Load-bearing thermal insulation elements for the connection of freely cantilevered steel constructions to steel structures.

      7. Balcony installation with flexible construction times
        1. Balcony installation with flexible construction times
        2. Overview
        3. Isokorb® IQ mit Dämmkörperdicke 80 mm
          1. IQ type K
        4. Isokorb® XT with insulating element thickness 120 mm
          1. XT type K-ID
          2. XT type Q-ID
        5. Isokorb® T with insulating element thickness 80 mm
          1. T type K-ID
          2. T type Q-ID
        Isokorb® IQ type K

        Tragendes Wärmedämmelement für die stützenfreie bauzeitenflexible Montage frei auskragender Balkone.

        IQ type K

        Tragendes Wärmedämmelement für die stützenfreie bauzeitenflexible Montage frei auskragender Balkone.

        Isokorb® XT type K-ID

        Load-bearing thermal insulation element for installation of cantilevered balconies with flexible construction times.

        XT type K-ID

        Load-bearing thermal insulation element for installation of cantilevered balconies with flexible construction times.

        XT type Q-ID

        Load-bearing thermal insulation element for installation of balconies supported from below with flexible construction times.

        Isokorb® T type K-ID

        Load-bearing thermal insulation element for installation of cantilevered balconies with flexible construction times.

        T type K-ID

        Load-bearing thermal insulation element for installation of cantilevered balconies with flexible construction times.

        T type Q-ID

        Load-bearing thermal insulation element for installation of balconies supported from below with flexible construction times.

      8. Refurbishment
        1. Refurbishment
        2. Overview
        3. Isokorb® T with insulating element thickness 80 mm for steel structures on steel
          1. T type S
        4. Isokorb® RT with insulating element thickness 80 mm
          1. RT type K
          2. RT type Q-P
          3. RT type SK
          4. RT type SQ
        Isokorb® T type S

        Load-bearing thermal insulation elements for the connection of freely cantilevered steel constructions to steel structures.

        T type S

        Load-bearing thermal insulation elements for the connection of freely cantilevered steel constructions to steel structures.

        Isokorb® RT type K

        Load-bearing thermal insulation element for cantilevered balconies with connection to existing reinforced concrete floor slabs.

        RT type K

        Load-bearing thermal insulation element for cantilevered balconies with connection to existing reinforced concrete floor slabs.

        RT type Q-P

        Load-bearing thermal insulation element<cbez class="NoBreak"/> for balconies supported from below with connection to existing reinforced concrete floor slabs.

        RT type SK

        Load-bearing thermal insulation element for cantilevered steel structures with connection to existing reinforced concrete floor slabs.

        RT type SQ

        Load-bearing thermal insulation element for steel structures supported from below with connection to existing reinforced concrete floor slabs.

    4. Tronsole®
      Impact sound insulation for stairs
      1. Tronsole®
      2. Overview
      3. Straight stair
        1. Straight stair
        2. Overview
          1. type T
          2. type F
          3. type B
          4. type L
        Type T

        Load-bearing impact sound insulation element for connecting staircases to landings.

        Type F

        Load-bearing impact sound insulation element for connecting precast staircases to landings.

        Type B

        Load-bearing impact sound insulation element for connecting staircases to floor slabs.

        Type L

        Impact sound insulation element to avoid acoustic bridges between staircase/landing and staircase wall.

      4. Winding staircase
        1. Winding staircase
        2. Overview
          1. type T
          2. type F
          3. type B
          4. type L
          5. type Q
        Type T

        Load-bearing impact sound insulation element for connecting staircases to landings.

        Type F

        Load-bearing impact sound insulation element for connecting precast staircases to landings.

        Type B

        Load-bearing impact sound insulation element for connecting staircases to floor slabs.

        Type L

        Impact sound insulation element to avoid acoustic bridges between staircase/landing and staircase wall.

        Type Q

        Load-bearing impact sound insulation element for connecting spiral staircases to staircase walls.

      5. Landing
        1. Landing
        2. Overview
          1. type L
          2. type Z
          3. type P
        Type L

        Impact sound insulation element to avoid acoustic bridges between staircase/landing and staircase wall.

        Type Z

        Load-bearing impact sound insulation element for connecting landings to staircase walls.

        Type P

        Serves as point bearing for acoustic decoupling of landings and staircase walls.

    5. Sconnex®
      Thermal Insulation for Walls & Columns
      1. Sconnex®
      2. Overview
      3. Type P
        Type P

        Load-bearing thermal insulation element for reinforced concrete columns.

      4. Type W
        Type W
      5. Type M
        Type M
    6. Isolink®
      Façade Fastening
      1. Isolink®
      2. Overview
      3. Concrete façades
        1. Concrete façades
        2. Overview
        3. Composite wall
          1. type C-EH
          2. type C-ED
        4. Sandwich wall
          1. type C-SH
          2. type C-SD
        Isolink® type C-EH

        Thermoanker for thermal breaks between core-insulated element and sandwich walls manufactured at a prefabricating plant, for supported façades.

        Isolink® type C-EH

        Thermoanker for thermal breaks between core-insulated element and sandwich walls manufactured at a prefabricating plant, for supported façades.

        Isolink® Typ C-ED

        Thermisch trennende Befestigung für kerngedämmte Elementwände mit freihängender Vorsatzschale. Er wird in Verbindung mit dem Isolink® Typ C-EH eingesetzt.

        Isolink® type C-SH

        Thermally insulating horizontal anchor with depth stop for sandwich walls.

        Isolink® type C-SH

        Thermally insulating horizontal anchor with depth stop for sandwich walls.

        Isolink® type C-SD

        Thermally insulating diagonal anchor with depth stop for sandwich walls.

        Concrete façades

        Thermally separating fastening for core-insulated concrete walls.

      4. Rainscreen cladding façades
        1. Rainscreen cladding façades
        2. Overview
        3. New Construction
          1. type F
        4. Renovation
          1. type F
        Isolink® type F

        Thermal break fastener for ventilated curtain-wall façades

        Isolink® type F

        Thermal break fastener for ventilated curtain-wall façades

        Rainscreen cladding façades

        Thermally separating fastening for ventilated curtain wall facades.

    7. Stacon®
      Shear Dowel
      1. Stacon®
      2. Overview
      3. Expansion Joint with High Loads
        Type SLD
        Expansion Joint with High Loads

        Heavy-duty dowel for transferring high shear forces in expansion joints.

      4. Expansion Joint with Low Loads
        Type LD
        Expansion Joint with Low Loads

        Heavy-duty dowel for transferring shear forces in expansion joints.

    8. Bole®
      Punching protection
      1. Bole®
      2. Overview
      3. After Reinforcement Placement
        Type O
        After Reinforcement Placement

        Reinforcement element to prevent punching shear failure in flat slabs or foundation slabs.

      4. Before Reinforcement Placement
        Type U
        Before Reinforcement Placement

        Reinforcement element to prevent punching shear failure in flat slabs or foundation slabs.

      5. Installation in the Precast Plant
        Type F
        Installation in the Precast Plant

        Reinforcement element to prevent punching shear failure in flat slabs made of hybrid precast elements.

    9. Combar®
      Glass Fiber Composite Material
      1. Combar®
      2. Overview
      3. Material properties
        Material properties

        Information on material components and manufacturing, as well as product properties and potential applications.

      4. Uses
        1. Uses
        2. Overview
        3. Industrial facilities and power plants
        4. Railway and track construction
        5. Tunnelling
        6. Medical facilities and research laboratories
        7. Concrete components at risk of corrosion
      5. Product overview
        Product overview

        Types and Accessories at a glance.

    10. Signo®
      Formwork Element
      1. Signo®
      2. Overview
      3. Stairwell Openings, Windows, Doors
        Type U-0
        Signo® Typ U-0

        Shuttering element for slabs and walls without sealing strip

      4. Slabs
        Type U-1
        Signo® Typ U-1

        Shuttering element for slabs and walls with one sealing strip

      5. Double Walls
        Type U-2
        Signo® Typ U-2

        Shuttering element for slabs and walls with two sealing strips

      6. Stair Supports, Precast Slabs
        Type P
        Signo® Typ P

        Shuttering element for precast floors and stair landings

  2. Applications
    1. Applications
    2. Overview
    3. Balcony, access balcony and canopy
      Balcony, access balcony and canopy
      Balcony, access balcony and canopy

      Balconies are not only visual highlights, but also often the weak point in thermal insulation. In addition to thermal insulation and statics, fire, sound and moisture protection must also be taken into account and the corresponding values adhered to.

    4. Walls and columns
      Walls and columns
      Walls and columns

      In connection details of walls and columns, thermal bridges lead to high energy losses - in addition, structural damage often occurs there due to condensation or mould. The Schöck Sconnex® thermal insulation element provides direct and permanent insulation.

    5. Parapet and roof superstructure
      Parapet and roof superstructure
      Parapet and roof superstructure

      Solid roof terraces and flat roofs are enclosed with a parapet or parapet. This leads to a thermal bridge and must be thermally separated. By connecting with Schöck Isokorb® , the internal insulation required for packing can be dispensed with.

    6. Reinforced Concrete Slabs
      Reinforced Concrete Slabs
      Reinforced Concrete Slabs

      Concrete ceilings are most frequently reinforced with steel. As they are complex to construct, there is a need for product solutions that can rationalise production.

    7. Stairs
      Stairs
      Stairs

      In addition to aesthetic design, stairs are increasingly focussing on functional and technical aspects. Standards, guidelines, technical regulations and client requirements must be taken into account - especially sound insulation and fire protection. This requires the use of special construction elements.

    8. Façade
      Façade
      Façade

      The façade is the face of a building - an architectural statement. At the same time, there are high demands on energy efficiency, e.g. the thermal insulation requirements of the GEG (Building Energy Act), which can only be met with appropriate building elements.

  3. Digital solutions
    1. Digital solutions
    2. Overview
    3. Structural calculation
      1. Structural calculation
      2. Overview
      3. Design software Scalix®
      4. Schöck Isokorb® steel – reinforced concrete
      5. Schöck Isokorb® steel – steel
      6. Schöck Isokorb® reinforced concrete – reinforced concrete
      7. Schöck Isolink® for core-insulated concrete walls
      8. Schöck Bole® to EC2
      9. Isokorb® type finder
    4. CAD / BIM
      1. CAD / BIM
      2. Overview
      3. CAD/BIM libraries
      4. Allplan
      5. Tekla
  4. Company
    1. Company
    2. Overview
    3. About Schöck
    4. News
    5. Awards and certificates
    6. Foundations
    7. Case studies
    8. Schöck History
    9. Press
  1. Contact
  2. Contact
Schöckstraße 1
76534 Baden-Baden
+49 7223 967-144
export@schoeck.com
  • Home
  • Solutions

Special solutions 
for high efficiency.

Reinforcement technology

Concrete is a building material that is indispensable in the modern world. In addition to its exceptional durability, concrete is also flexibly moldable and highly resistant to compression. However, the weak point of this material lies in its tensile strength.

Impact sound insulation

Peace and quiet are a basic human need, especially within one’s own four walls. However, this tranquility can quickly be disrupted by noise from neighboring rooms or the staircase. One of the main causes is impact sound.

Thermal insulation

Climate protection and sustainability are becoming increasingly important for the construction industry, as evidenced, among other things, by the growing number of legal requirements. Thermal insulation in buildings is therefore gaining ever greater significance.

The Schöck
product portfolio

Schöck is a specialist in the field of construction, providing fully-fledged products and solutions for thermal insulation, impact sound insulation and reinforcement technology.

Isokorb®

Load-bearing thermal insulation elements for cantilevered components.

Tronsole®

Pre-fabricated impact sound insulation elements for all connections in the staircase.

Sconnex®

Thermal separation for walls and columns.

Isolink®

Thermally separating fastening for façade systems.

Stacon®

Pre-assembled shear and heavy-duty dowels for the transfer of shear forces in expansion joints.

Bole®

Reliable punching shear reinforcement for flat slabs.

Combar®

Pioneering glass fiber reinforcement for diverse applications as an alternative to reinforcing steel.

Signo®

Pre-assembled concrete formwork for precast elements.


Schöckstraße 1
76534 Baden-Baden
+49 7223 967-144 or export@schoeck.com
  • Downloads
  • Case studies
  • Contact
© 2025 Schöck Bauteile GmbH
  • AGB
  • AEB
  • Privacy Policy
  • Imprint
+49 7223 967-144
export@schoeck.com