Tronsole®
F

Tragendes Trittschalldämmelement für den Anschluss Fertigteiltreppenlauf an Podest. Das Element überträgt positive Querkräfte.

Technical approval
Building material class B1 in accordance with abZ to DIN 4102
Cross-sectional view of installation

Advantages

  • Outstanding soundproofing
    SSt III to VDI 4100 is achieved in a standard apartment building with all Tronsole® − and also DEGA class A with certain product types

     

  • Reliable and comparable sound attenuation values
    Acoustic characteristic values of Schöck Tronsole® tested to DIN 7396; describes a method of measuring impact sound insulating elements for solid stairs and landings and enables comparison of decoupling elements

     

  • Acoustic characteristic values tested to DIN 7396
    Evaluated impact sound pressure level difference ∆L*w, stair ≥ 28 dB for load-bearing level V1, ∆L*w, stair ≥ 26 dB for load-bearing level V2

     

  • Technical approval
    Planning reliability with DIBt (German Institute of Building Technology) approval Z-15.7-359

     

  • Certified fire protection
    Satisfies fire protection requirements up to R 90; use in rescue routes confirmed by fire performance assessments

     

  • Integrated adhesive strips
    Can be glued to the prefabricated part to ensure the bracket bearing does not slip when the stair is moved; for fast efficient construction

     

  • Practical standard lengths
    6 lengths for straightforward cutting to length and to reduce offcuts

     

  • Clip hinge
    For high dimensional stability and straightforward handling of Schöck Tronsole® when setting down the stair